PLD6000 high frequency digital X-ray system |
function |
gastrointestinal fluoroscopy/radiography, gastrointestinal examination, chest radiography, head and whole body bone radiography
gastrography, Esophagography, Myelography, Arthrography, cholangiography, bronchography, venography, angiography, urography, hysterosalpingography, Pediatric Radiology, treat application of several intervention radiology |
Features |
- base the optimization principle to produce, excellent config of whole system, satisfy clinical personalized requirement
- latest technology of high frequency mainframe, digital image collection, gain the high quality image easily
- show human-machine interface directly, excellent operation system, make man-machine conversation more conveniently and easy to understand
- multiple safety control, make the image quality and radiation dose to achieve organic balance
- strong function of digital image processing, overall compatible with DICOM network application
|
|
Item |
Content |
Technical parameter |
Power supply |
Voltage |
380V±38V |
Frequency |
50Hz±1Hz |
Capacity |
≥65kVA |
internal resistor |
≤0.17Ω |
Digital X-ray high voltage system (import high-frequency generator ) |
|
Power Output |
50KW |
photography |
Tube Voltage |
40kv—150kv step regulation |
Tube Current |
10mA—630mA step regulation |
Exposure time |
1.0s—6300ms step regulation |
Control interface |
Touched LCD |
fluoroscopy |
Tube Voltage |
40kv—125kv step:2kv continuous regulation |
Tube Current |
0.5mA—6mA continuous regulation |
Automatic brightness for fluoroscopy IBS |
Automatic brightness tracking,multiple settings beforehand |
Digital Controlled X-ray Tube
(Toshiba, Japanese) |
Model |
E7252 |
Tube Focus:Large Focus/Small Focus |
1.2mm /0.6mm |
Input Power |
Large focus:75kW small focus: 27kW |
thermal capacity |
210KJ |
Rotary anode speed |
2700rpm |
Micro-computer control digital tube remote diagnostic table |
Material of the tabletop |
high strength,low absorb carbon fiber |
Rotation of the table |
90°~0°~-25° |
Transverse travel of table |
±110mm |
Longitudinal travel of the photography holder and film spot device |
≥720mm |
X-ray Focus—film gauge |
1100 mm—1500 mm |
Rotating foot plate |
±360° rotation |
Full film photography size |
8″×10″—14″×17″ |
Dividing method for spot film |
Full film, half dividing, three parts dividing, four parts dividing |
Control method for diagnostic table |
Remote,table control,frequency conversion soft starting and stopping |
beam limiter |
Electric Multi-leaf |
Voice interaction |
Two-way microphone system |
fixed bucky device for table |
density 103L/INCH,grid:10:1 converge distance:120cm,fixed:15″×18″ |
Digital Image TV System |
Image Intensifier |
TOSHIBA (9″) Image Intensifier |
high resolution CCD (digital cameras) |
ultra-low-light,standard 0.47 mega-pixel
(selecting 1 mega-pixel) |
Monitor |
14"medical HDTV monitor,Horizontal center resolution 1000/L, edge 800/L Visual bandwidth12.5MHz 10t Image 25/s |
Digital Picture Processing System
(CCU Sentinel) |
High Definition progressive output mode, 8 level Noise Reduction,8 image storage, LIH, Vertical Image, Horizontal image flip, positive or negative image and OSD |
Price was changed recently, so please send us email to sales@mobile-cr.com that we could provide you with update price information.
Please Choose:
Add to Cart:
|
This product was added to our catalog on Friday 20 April, 2012.
|
There currently are 85 guests online.
|