Welcome, Sign In   |   First time visitor? Create a New Account
Phone: (262)344-5999
Fax: 1(888)875-8882
E-mail: sales@mobile-cr.com

Anaesthesia Machine

  • Model: AM-900B
  • Units in Stock: 9

$10,790.00

Features:

Advanced versatile anaesthesia machine with more working modes including IPPV, VCV, PCV, SIMV, SIGH, MANUAL, STANDY, DEMO for selection
10.4-inch TFT color screen showing P-t & F-t dual channel waveform
Adopts integrated computer controlled high speed data processing system with high reliability and advanced technology

Anesthesia Machine:

Patient: Adult, Pediatric
Driven mode: Pneumatically driven electronically controlled
Mode: Semi-open, Semi0closed or closed system
Power supply: 110/220V +/- 10%, 50/60Hz +/-1Hz
Internal battery: DC12V( over 4 hours)
Power consumption: ≤50W
Dimension: 910W x 618L x 1355H(mm)
Net weight: 112Kg

Main Unit:

Circle absorber: compact circle absorber
Bellow: 0-1600ml
Gauge: 4 units, one is for N2O, one is for Air, two is for O2
Flow meter(backlight design):
O2, N2O, Air five-tube flow meter
O2 flow meter: 0L/min~1L/mim~10L/min
N2O flow meter: 0L/min~1L/mim~10L/min
Air flow meter range: 0L/min~10L/min
O2 and N2O Linkage Device
Adjust O2 and N2O in proportion(O2 concentration is not lower than 25%)
Fast for oxygen:35L/min—75L/min
Gas source pressure

O2: 0.27MPa—0.55MPa

N2O: 0.27MPa—0.55Mpa

Air: 0.27MPa—0.55MPa

Anesthetic Vaporizer: two high precise vaporizers

Anaesthesia Ventilator:

Respiration Pattern: IPPV,VCV,PCV,SIMV,SIGH,MANUAL,STANDBY,DEMO
Display: 10.4 TFT color screen
Waveform: P-t, F-t
Tidal Volume: 20ml to 1600ml
Respiratory frequency: 1 to 65bpm
I:E ratio: 8:1--1:8
Inspiration pause: 0--50%Ti
Inspiration Pressure: 1--60cmH2O
Trigger Pressure: -10--10cmH2O
Pressure Alarm setting: High Alarm limit Set 1--60cmH2O,Low Alarm limit Set 0--20cmH2O
O2 Concentration Alarm setting: High Alarm limit Set 21--99%, Low Alarm limit Set 21--50%
MV Alarm setting: High Alarm limit Set 10--99L/min, Low Alarm Limit Set 0--40L/min
Monitoring Parameter (under both manual and control modes):
O2 concentration, MV, respiratory frequency, tidal volume, airway average pressure, PEEP, I:E ratio, air maximum pressure etc.
Alarm parameters: pressure high alarm, pressure low alarm, O2 concentration high alarm, O2 concentration low alarm, MV high alarm, MV low alarm, AC power lost alarm, O2 lost alarm etc.
Alarm silence function

Add to Cart:



This product was added to our catalog on Wednesday 28 March, 2012.

Copyright © 2024 xray chicago. Designed by 12leaves.com
Your IP Address is: 18.119.162.226
warobbo template